Vulnerabilities (CVE)

Filtered by vendor Schneider-electric Subscribe
Total 758 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2017-5157 2 Schneider-electric, Schneider Electric 2 Homelynk Controller Lss100100, Homelynk Controller Lss100100 Firmware 2025-04-20 4.3 MEDIUM 6.1 MEDIUM
An issue was discovered in Schneider Electric homeLYnk Controller, LSS100100, all versions prior to V1.5.0. The homeLYnk controller is susceptible to a cross-site scripting attack. User inputs can be manipulated to cause execution of JavaScript code.
CVE-2016-5815 1 Schneider-electric 6 Ion5000, Ion7300, Ion7500 and 3 more 2025-04-20 7.5 HIGH 9.8 CRITICAL
An issue was discovered on Schneider Electric IONXXXX series power meters ION73XX series, ION75XX series, ION76XX series, ION8650 series, ION8800 series, and PM5XXX series. No authentication is configured by default. An unauthorized user can access the device management portal and make configuration changes.
CVE-2017-13997 1 Schneider-electric 2 Wonderware Indusoft Web Studio, Wonderware Intouch 2025-04-20 10.0 HIGH 9.8 CRITICAL
A Missing Authentication for Critical Function issue was discovered in Schneider Electric InduSoft Web Studio v8.0 SP2 or prior, and InTouch Machine Edition v8.0 SP2 or prior. InduSoft Web Studio provides the capability for an HMI client to trigger script execution on the server for the purposes of performing customized calculations or actions. A remote malicious entity could bypass the server authentication and trigger the execution of an arbitrary command. The command is executed under high privileges and could lead to a complete compromise of the server.
CVE-2017-14024 1 Schneider-electric 2 Wonderware Indusoft Web Studio, Wonderware Intouch 2025-04-20 10.0 HIGH 9.8 CRITICAL
A Stack-based Buffer Overflow issue was discovered in Schneider Electric InduSoft Web Studio v8.0 SP2 Patch 1 and prior versions, and InTouch Machine Edition v8.0 SP2 Patch 1 and prior versions. The stack-based buffer overflow vulnerability has been identified, which may allow remote code execution with high privileges.
CVE-2015-3977 1 Schneider-electric 1 Imt25 Magnetic Flow Dtm 2025-04-12 7.7 HIGH N/A
Buffer overflow in Schneider Electric IMT25 Magnetic Flow DTM before 1.500.004 for the HART Protocol allows remote authenticated users to execute arbitrary code or cause a denial of service (memory corruption) via a crafted HART reply.
CVE-2015-0998 2 Aveva, Schneider-electric 2 Aveva Edge, Wonderware Intouch 2014 2025-04-12 3.3 LOW N/A
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 transmit cleartext credentials, which allows remote attackers to obtain sensitive information by sniffing the network.
CVE-2016-4529 1 Schneider-electric 3 M171, M172, Somachine Hvac Firmware 2025-04-12 7.5 HIGH 7.3 HIGH
An unspecified ActiveX control in Schneider Electric SoMachine HVAC Programming Software for M171/M172 Controllers before 2.1.0 allows remote attackers to execute arbitrary code via unknown vectors, related to the INTERFACESAFE_FOR_UNTRUSTED_CALLER (aka safe for scripting) flag.
CVE-2015-3940 1 Schneider-electric 1 Wonderware System Platform 2014 2025-04-12 6.9 MEDIUM N/A
Untrusted search path vulnerability in Schneider Electric Wonderware System Platform before 2014 R2 Patch 01 allows local users to gain privileges via a Trojan horse DLL in an unspecified directory.
CVE-2016-4513 1 Schneider-electric 2 Powerlogic Pm8ecc, Powerlogic Pm8ecc Firmware 2025-04-12 4.3 MEDIUM 6.1 MEDIUM
Cross-site scripting (XSS) vulnerability in the Schneider Electric PowerLogic PM8ECC module before 2.651 for PowerMeter 800 devices allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
CVE-2015-7937 1 Schneider-electric 13 Bmxnoc0401, Bmxnoe0100, Bmxnoe0100h and 10 more 2025-04-12 10.0 HIGH N/A
Stack-based buffer overflow in the GoAhead Web Server on Schneider Electric Modicon M340 PLC BMXNOx and BMXPx devices allows remote attackers to execute arbitrary code via a long password in HTTP Basic Authentication data.
CVE-2014-9206 1 Schneider-electric 1 Device Type Manager 2025-04-12 6.9 MEDIUM N/A
Stack-based buffer overflow in Device Type Manager (DTM) 3.1.6 and earlier for Schneider Electric Invensys SRD Control Valve Positioner devices 960 and 991 allows local users to gain privileges via a malformed DLL file.
CVE-2015-7921 1 Schneider-electric 4 Proface Gp-pro Ex Ex-ed, Proface Gp-pro Ex Pfxexedls, Proface Gp-pro Ex Pfxexedv and 1 more 2025-04-12 6.4 MEDIUM 9.1 CRITICAL
The FTP server in Pro-face GP-Pro EX EX-ED before 4.05.000, PFXEXEDV before 4.05.000, PFXEXEDLS before 4.05.000, and PFXEXGRPLS before 4.05.000 has hardcoded credentials, which makes it easier for remote attackers to bypass authentication by leveraging knowledge of these credentials.
CVE-2015-6485 1 Schneider-electric 8 Sage 1410, Sage 1430, Sage 1450 and 5 more 2025-04-12 5.0 MEDIUM 5.3 MEDIUM
Schneider Electric Telvent Sage 2300 RTUs with firmware before C3413-500-S01, and LANDAC II-2, Sage 1410, Sage 1430, Sage 1450, Sage 2400, and Sage 3030M RTUs with firmware before C3414-500-S02J2, allow remote attackers to obtain sensitive information from device memory by reading a padding field of an Ethernet packet.
CVE-2015-0999 2 Aveva, Schneider-electric 2 Aveva Edge, Wonderware Intouch 2014 2025-04-12 2.1 LOW N/A
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 store cleartext OPC User credentials in a configuration file, which allows local users to obtain sensitive information by reading this file.
CVE-2015-3963 2 Schneider-electric, Windriver 14 Sage 1210, Sage 1230, Sage 1250 and 11 more 2025-04-12 5.8 MEDIUM N/A
Wind River VxWorks before 5.5.1, 6.5.x through 6.7.x before 6.7.1.1, 6.8.x before 6.8.3, 6.9.x before 6.9.4.4, and 7.x before 7 ipnet_coreip 1.2.2.0, as used on Schneider Electric SAGE RTU devices before J2 and other devices, does not properly generate TCP initial sequence number (ISN) values, which makes it easier for remote attackers to spoof TCP sessions by predicting an ISN value.
CVE-2014-8390 1 Schneider-electric 1 Vampset 2025-04-12 4.4 MEDIUM N/A
Multiple buffer overflows in Schneider Electric VAMPSET before 2.2.168 allow local users to gain privileges via malformed disturbance-recording data in a (1) CFG or (2) DAT file.
CVE-2016-2290 1 Schneider-electric 4 Proface Gp-pro Ex Ex-ed, Proface Gp-pro Ex Pfxexedls, Proface Gp-pro Ex Pfxexedv and 1 more 2025-04-12 6.8 MEDIUM 8.8 HIGH
Heap-based buffer overflow in Pro-face GP-Pro EX EX-ED before 4.05.000, PFXEXEDV before 4.05.000, PFXEXEDLS before 4.05.000, and PFXEXGRPLS before 4.05.000 allows remote attackers to execute arbitrary code via unspecified vectors.
CVE-2015-0997 2 Aveva, Schneider-electric 2 Aveva Edge, Wonderware Intouch 2014 2025-04-12 5.0 MEDIUM N/A
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 provide an HMI user interface that lists all valid usernames, which makes it easier for remote attackers to obtain access via a brute-force password-guessing attack.
CVE-2013-0662 2 Schneider-electric, Schneider Electric 13 Concept, Modbus Serial Driver, Modbuscommdtm Sl and 10 more 2025-04-12 9.3 HIGH N/A
Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header.
CVE-2015-0996 2 Aveva, Schneider-electric 2 Aveva Edge, Wonderware Intouch 2014 2025-04-12 2.1 LOW N/A
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 rely on a hardcoded cleartext password to control read access to Project files and Project Configuration files, which makes it easier for local users to obtain sensitive information by discovering this password.