CVE-2025-5825

Autel MaxiCharger AC Wallbox Commercial Firmware Downgrade Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Autel MaxiCharger AC Wallbox Commercial charging stations. An attacker must first obtain the ability to pair a malicious Bluetooth device with the target system in order to exploit this vulnerability. The specific flaw exists within the firmware update process. The issue results from the lack of proper validation of a firmware image before using it to perform an upgrade. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the device. Was ZDI-CAN-26354.
References
Configurations

Configuration 1 (hide)

AND
OR cpe:2.3:o:autel:maxicharger_ac_elite_business_c50_firmware:*:*:*:*:*:*:*:american_standard
cpe:2.3:o:autel:maxicharger_ac_elite_business_c50_firmware:*:*:*:*:*:*:*:european_standard
cpe:2.3:h:autel:maxicharger_ac_elite_business_c50:-:*:*:*:*:*:*:*

Configuration 2 (hide)

AND
OR cpe:2.3:o:autel:maxicharger_ac_pro_firmware:*:*:*:*:*:*:*:american_standard
cpe:2.3:o:autel:maxicharger_ac_pro_firmware:*:*:*:*:*:*:*:european_standard
cpe:2.3:h:autel:maxicharger_ac_pro:-:*:*:*:*:*:*:*

Configuration 3 (hide)

AND
OR cpe:2.3:o:autel:maxicharger_ac_ultra_firmware:*:*:*:*:*:*:*:american_standard
cpe:2.3:o:autel:maxicharger_ac_ultra_firmware:*:*:*:*:*:*:*:european_standard
cpe:2.3:h:autel:maxicharger_ac_ultra:-:*:*:*:*:*:*:*

Configuration 4 (hide)

AND
OR cpe:2.3:o:autel:maxicharger_dc_compact_mobile_firmware:*:*:*:*:*:*:*:american_standard
cpe:2.3:o:autel:maxicharger_dc_compact_mobile_firmware:*:*:*:*:*:*:*:european_standard
cpe:2.3:h:autel:maxicharger_dc_compact_mobile:-:*:*:*:*:*:*:*

Configuration 5 (hide)

AND
OR cpe:2.3:o:autel:maxicharger_dc_compact_pedestal_firmware:*:*:*:*:*:*:*:american_standard
cpe:2.3:o:autel:maxicharger_dc_compact_pedestal_firmware:*:*:*:*:*:*:*:european_standard
cpe:2.3:h:autel:maxicharger_dc_compact_pedestal:-:*:*:*:*:*:*:*

Configuration 6 (hide)

AND
OR cpe:2.3:o:autel:maxicharger_dc_fast_firmware:*:*:*:*:*:*:*:american_standard
cpe:2.3:o:autel:maxicharger_dc_fast_firmware:*:*:*:*:*:*:*:european_standard
cpe:2.3:h:autel:maxicharger_dc_fast:-:*:*:*:*:*:*:*

Configuration 7 (hide)

AND
OR cpe:2.3:o:autel:maxicharger_dc_hipower_firmware:*:*:*:*:*:*:*:american_standard
cpe:2.3:o:autel:maxicharger_dc_hipower_firmware:*:*:*:*:*:*:*:european_standard
cpe:2.3:h:autel:maxicharger_dc_hipower:-:*:*:*:*:*:*:*

Configuration 8 (hide)

AND
OR cpe:2.3:o:autel:maxicharger_dh480_firmware:*:*:*:*:*:*:*:american_standard
cpe:2.3:o:autel:maxicharger_dh480_firmware:*:*:*:*:*:*:*:european_standard
cpe:2.3:h:autel:maxicharger_dh480:-:*:*:*:*:*:*:*

Configuration 9 (hide)

AND
OR cpe:2.3:o:autel:maxicharger_single_charger_firmware:*:*:*:*:*:*:*:american_standard
cpe:2.3:o:autel:maxicharger_single_charger_firmware:*:*:*:*:*:*:*:european_standard
cpe:2.3:h:autel:maxicharger_single_charger:-:*:*:*:*:*:*:*

History

No history.

Information

Published : 2025-06-25 18:15

Updated : 2025-09-10 14:46


NVD link : CVE-2025-5825

Mitre link : CVE-2025-5825

CVE.ORG link : CVE-2025-5825


JSON object : View

Products Affected

autel

  • maxicharger_dc_fast_firmware
  • maxicharger_ac_ultra
  • maxicharger_ac_elite_business_c50_firmware
  • maxicharger_dc_compact_pedestal_firmware
  • maxicharger_dh480_firmware
  • maxicharger_dh480
  • maxicharger_dc_hipower_firmware
  • maxicharger_dc_hipower
  • maxicharger_dc_compact_pedestal
  • maxicharger_ac_pro
  • maxicharger_dc_fast
  • maxicharger_single_charger
  • maxicharger_dc_compact_mobile
  • maxicharger_single_charger_firmware
  • maxicharger_dc_compact_mobile_firmware
  • maxicharger_ac_pro_firmware
  • maxicharger_ac_ultra_firmware
  • maxicharger_ac_elite_business_c50
CWE
CWE-1328

Security Version Number Mutable to Older Versions