Heap-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'ShowSupervisorParameters()' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf()'. The 'GetParameter(meter)' function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the 'meter' parameter.
References
| Link | Resource |
|---|---|
| https://www.incibe.es/en/incibe-cert/notices/aviso-sci/multiple-vulnerabilities-circutor-products-0 | Third Party Advisory |
Configurations
History
03 Dec 2025, 19:19
| Type | Values Removed | Values Added |
|---|---|---|
| References | () https://www.incibe.es/en/incibe-cert/notices/aviso-sci/multiple-vulnerabilities-circutor-products-0 - Third Party Advisory | |
| CPE | cpe:2.3:o:circutor:sge-plc1000_firmware:9.0.2:*:*:*:*:*:*:* cpe:2.3:h:circutor:sge-plc1000:-:*:*:*:*:*:*:* cpe:2.3:h:circutor:sge-plc50:-:*:*:*:*:*:*:* cpe:2.3:o:circutor:sge-plc50_firmware:9.0.2:*:*:*:*:*:*:* |
|
| CVSS |
v2 : v3 : |
v2 : unknown
v3 : 9.8 |
| First Time |
Circutor sge-plc50
Circutor sge-plc1000 Firmware Circutor sge-plc50 Firmware Circutor Circutor sge-plc1000 |
02 Dec 2025, 13:15
| Type | Values Removed | Values Added |
|---|---|---|
| New CVE |
Information
Published : 2025-12-02 13:15
Updated : 2025-12-03 19:19
NVD link : CVE-2025-11788
Mitre link : CVE-2025-11788
CVE.ORG link : CVE-2025-11788
JSON object : View
Products Affected
circutor
- sge-plc50
- sge-plc1000_firmware
- sge-plc1000
- sge-plc50_firmware
CWE
CWE-122
Heap-based Buffer Overflow