CVE-2024-3493

A specific malformed fragmented packet type (fragmented packets may be generated automatically by devices that send large amounts of data) can cause a major nonrecoverable fault (MNRF) Rockwell Automation's ControlLogix 5580, Guard Logix 5580, CompactLogix 5380, and 1756-EN4TR. If exploited, the affected product will become unavailable and require a manual restart to recover it. Additionally, an MNRF could result in a loss of view and/or control of connected devices.
Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:rockwellautomation:controllogix_5580_firmware:35.011:*:*:*:*:*:*:*
cpe:2.3:h:rockwellautomation:controllogix_5580:-:*:*:*:*:*:*:*

Configuration 2 (hide)

AND
cpe:2.3:o:rockwellautomation:guardlogix_5580_firmware:35.011:*:*:*:*:*:*:*
cpe:2.3:h:rockwellautomation:guardlogix_5580:-:*:*:*:*:*:*:*

Configuration 3 (hide)

AND
cpe:2.3:o:rockwellautomation:compactlogix_5380_firmware:35.011:*:*:*:*:*:*:*
cpe:2.3:h:rockwellautomation:compactlogix_5380:-:*:*:*:*:*:*:*

Configuration 4 (hide)

AND
cpe:2.3:o:rockwellautomation:compact_guardlogix_5380_firmware:35.011:*:*:*:*:*:*:*
cpe:2.3:h:rockwellautomation:compact_guardlogix_5380:-:*:*:*:*:*:*:*

Configuration 5 (hide)

AND
cpe:2.3:o:rockwellautomation:1756-en4tr_firmware:5.001:*:*:*:*:*:*:*
cpe:2.3:h:rockwellautomation:1756-en4tr:-:*:*:*:*:*:*:*

Configuration 6 (hide)

AND
cpe:2.3:o:rockwellautomation:controllogix_5580_process_firmware:35.011:*:*:*:*:*:*:*
cpe:2.3:h:rockwellautomation:controllogix_5580_process:-:*:*:*:*:*:*:*

Configuration 7 (hide)

AND
cpe:2.3:o:rockwellautomation:compactlogix_5380_process_firmware:35.011:*:*:*:*:*:*:*
cpe:2.3:h:rockwellautomation:compactlogix_5380_process:-:*:*:*:*:*:*:*

Configuration 8 (hide)

AND
cpe:2.3:o:rockwellautomation:compactlogix_5480_firmware:35.011:*:*:*:*:*:*:*
cpe:2.3:h:rockwellautomation:compactlogix_5480:-:*:*:*:*:*:*:*

History

No history.

Information

Published : 2024-04-15 22:15

Updated : 2025-03-04 17:43


NVD link : CVE-2024-3493

Mitre link : CVE-2024-3493

CVE.ORG link : CVE-2024-3493


JSON object : View

Products Affected

rockwellautomation

  • guardlogix_5580_firmware
  • compactlogix_5480_firmware
  • compact_guardlogix_5380_firmware
  • controllogix_5580_process_firmware
  • compactlogix_5380_process_firmware
  • compactlogix_5480
  • compact_guardlogix_5380
  • controllogix_5580_process
  • controllogix_5580
  • compactlogix_5380_firmware
  • compactlogix_5380_process
  • 1756-en4tr_firmware
  • compactlogix_5380
  • guardlogix_5580
  • 1756-en4tr
  • controllogix_5580_firmware
CWE
CWE-20

Improper Input Validation

NVD-CWE-noinfo