{"id": "CVE-2021-22703", "cveTags": [], "metrics": {"cvssMetricV2": [{"type": "Primary", "source": "
[email protected]", "cvssData": {"version": "2.0", "baseScore": 5.0, "accessVector": "NETWORK", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "authentication": "NONE", "integrityImpact": "NONE", "accessComplexity": "LOW", "availabilityImpact": "NONE", "confidentialityImpact": "PARTIAL"}, "acInsufInfo": false, "impactScore": 2.9, "baseSeverity": "MEDIUM", "obtainAllPrivilege": false, "exploitabilityScore": 10.0, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}], "cvssMetricV31": [{"type": "Primary", "source": "
[email protected]", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 7.5, "attackVector": "NETWORK", "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "integrityImpact": "NONE", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "NONE", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 3.6, "exploitabilityScore": 3.9}]}, "published": "2021-02-19T16:15:13.157", "references": [{"url": "https://www.se.com/ww/en/download/document/SEVD-2021-040-01/", "tags": ["Mitigation", "Vendor Advisory"], "source": "
[email protected]"}, {"url": "https://www.se.com/ww/en/download/document/SEVD-2021-040-01/", "tags": ["Mitigation", "Vendor Advisory"], "source": "af854a3a-2127-422b-91ae-364da2661108"}], "vulnStatus": "Modified", "weaknesses": [{"type": "Primary", "source": "
[email protected]", "description": [{"lang": "en", "value": "CWE-319"}]}], "descriptions": [{"lang": "en", "value": "A CWE-319: Cleartext transmission of sensitive information vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause disclosure of user credentials when a malicious actor intercepts HTTP network traffic between a user and the device."}, {"lang": "es", "value": "Una CWE-319: Se presenta una vulnerabilidad de transmisi\u00f3n de informaci\u00f3n confidencial en texto sin cifrar en PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 y PM800 (consulte la notificaci\u00f3n para las versiones afectadas), que podr\u00eda causar una divulgaci\u00f3n de las credenciales del usuario cuando un actor malicioso intercepta el tr\u00e1fico de red HTTP entre un usuario y el dispositivo"}], "lastModified": "2024-11-21T05:50:29.640", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion7400_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "DCE7015C-02DD-44A1-ADEE-5E71CE312266", "versionEndExcluding": "3.0.0"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion7400:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "C8F28EAA-FC60-4CE0-BD39-DFD3EB88E195"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion7650_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "C1647241-A18D-4E4C-A118-8809EA625FC7"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion7650:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "0DF2D964-79EF-43F2-9AC6-D263F75BAFA0"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion8600_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "DB6B0276-AB51-4B8F-B2A7-85EDD56C9E7C"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion8600:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "324CF58A-753C-4D9C-8E72-FC8EE26EDA0D"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion8650_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "5D91486A-36CD-49A9-8A45-EDAA75F05E50", "versionEndIncluding": "4.31.2"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion8650:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "FBC3A306-D4F4-4C2A-9D60-DD8F0826AEEC"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion8800_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "C95DCE16-BAA5-46DD-835B-2299376387CD"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion8800:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "46E8E79E-6DA7-4094-9622-3B91D5913493"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion9000_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "32067EA8-5153-4A00-9DE8-C4BEC42C00A6", "versionEndExcluding": "3.0.0"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion9000:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "6718EAAA-074D-4807-AC2D-DD0A06D397FB"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:powerlogic_pm8000_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "E5A75862-E1AC-4C6E-83AD-DE5FCD8BA50D", "versionEndExcluding": "3.0.0"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:powerlogic_pm8000:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "B16A7BEC-1BED-4A61-A6C9-BF7DB13B998C"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion8300_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "1047C892-B7F5-49FB-AB36-8E8061A58037"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion8300:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "F01E9FE2-4110-4A6D-99F3-49784808D951"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion8400_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "70BAC583-6101-4F26-A264-26E5D69E9188"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion8400:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "82527983-6167-4D7B-A70A-D1A814ED3D06"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion8500_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "768FB179-B6D7-457C-9795-310400460F6E"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion8500:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "75E37742-CFF9-4F80-9B6A-0D4F5AD23112"}], "operator": "OR"}], "operator": "AND"}], "sourceIdentifier": "
[email protected]"}