CVE-2020-7533

CWE-287: Improper Authentication vulnerability exists which could cause the execution of commands on the webserver without authentication when sending specially crafted HTTP requests.
Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420302_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:modicon_m340_bmxp3420302:-:*:*:*:*:*:*:*

Configuration 2 (hide)

AND
cpe:2.3:o:schneider-electric:modicon_m340_bmxp342000_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:modicon_m340_bmxp342000:-:*:*:*:*:*:*:*

Configuration 3 (hide)

AND
cpe:2.3:o:schneider-electric:modicon_m340_bmxp341000_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:modicon_m340_bmxp341000:-:*:*:*:*:*:*:*

Configuration 4 (hide)

AND
cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420102_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:modicon_m340_bmxp3420102:-:*:*:*:*:*:*:*

Configuration 5 (hide)

AND
cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420302_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:modicon_m340_bmxp3420302:-:*:*:*:*:*:*:*

Configuration 6 (hide)

AND
cpe:2.3:o:schneider-electric:bmxnoe0100_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:bmxnoe0100:-:*:*:*:*:*:*:*

Configuration 7 (hide)

AND
cpe:2.3:o:schneider-electric:bmxnoe0110_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:bmxnoe0110:-:*:*:*:*:*:*:*

Configuration 8 (hide)

AND
cpe:2.3:o:schneider-electric:bmxnoc0401_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:bmxnoc0401:-:*:*:*:*:*:*:*

Configuration 9 (hide)

AND
cpe:2.3:o:schneider-electric:tsxp574634_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:tsxp574634:-:*:*:*:*:*:*:*

Configuration 10 (hide)

AND
cpe:2.3:o:schneider-electric:tsxp575634_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:tsxp575634:-:*:*:*:*:*:*:*

Configuration 11 (hide)

AND
cpe:2.3:o:schneider-electric:tsxp576634_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:tsxp576634:-:*:*:*:*:*:*:*

Configuration 12 (hide)

AND
cpe:2.3:o:schneider-electric:tsxety4103_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:tsxety4103:-:*:*:*:*:*:*:*

Configuration 13 (hide)

AND
cpe:2.3:o:schneider-electric:tsxety5103_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:tsxety5103:-:*:*:*:*:*:*:*

Configuration 14 (hide)

AND
cpe:2.3:o:schneider-electric:140noe77111_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:140noe77111:-:*:*:*:*:*:*:*

Configuration 15 (hide)

AND
cpe:2.3:o:schneider-electric:140noc78000_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:140noc78000:-:*:*:*:*:*:*:*

Configuration 16 (hide)

AND
cpe:2.3:o:schneider-electric:140noc77101_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:140noc77101:-:*:*:*:*:*:*:*

Configuration 17 (hide)

AND
cpe:2.3:o:schneider-electric:140cpu65260_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:140cpu65260:-:*:*:*:*:*:*:*

History

No history.

Information

Published : 2020-12-01 15:15

Updated : 2025-06-10 08:15


NVD link : CVE-2020-7533

Mitre link : CVE-2020-7533

CVE.ORG link : CVE-2020-7533


JSON object : View

Products Affected

schneider-electric

  • modicon_m340_bmxp341000
  • tsxp574634_firmware
  • 140cpu65260
  • modicon_m340_bmxp342000
  • 140noc78000
  • modicon_m340_bmxp341000_firmware
  • modicon_m340_bmxp3420302
  • 140noc77101
  • tsxp574634
  • bmxnoe0100
  • bmxnoe0110
  • bmxnoc0401_firmware
  • bmxnoe0110_firmware
  • 140cpu65260_firmware
  • tsxp575634_firmware
  • modicon_m340_bmxp3420102
  • tsxp575634
  • 140noe77111
  • tsxp576634_firmware
  • tsxp576634
  • tsxety5103_firmware
  • modicon_m340_bmxp342000_firmware
  • bmxnoe0100_firmware
  • modicon_m340_bmxp3420102_firmware
  • tsxety4103_firmware
  • 140noc77101_firmware
  • 140noe77111_firmware
  • modicon_m340_bmxp3420302_firmware
  • 140noc78000_firmware
  • bmxnoc0401
  • tsxety5103
  • tsxety4103
CWE
CWE-287

Improper Authentication

NVD-CWE-noinfo