{"id": "CVE-2020-6965", "cveTags": [], "metrics": {"cvssMetricV2": [{"type": "Primary", "source": "
[email protected]", "cvssData": {"version": "2.0", "baseScore": 6.5, "accessVector": "NETWORK", "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "authentication": "SINGLE", "integrityImpact": "PARTIAL", "accessComplexity": "LOW", "availabilityImpact": "PARTIAL", "confidentialityImpact": "PARTIAL"}, "acInsufInfo": false, "impactScore": 6.4, "baseSeverity": "MEDIUM", "obtainAllPrivilege": false, "exploitabilityScore": 8.0, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}], "cvssMetricV31": [{"type": "Primary", "source": "
[email protected]", "cvssData": {"scope": "CHANGED", "version": "3.1", "baseScore": 9.9, "attackVector": "NETWORK", "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "LOW", "confidentialityImpact": "HIGH"}, "impactScore": 6.0, "exploitabilityScore": 3.1}]}, "published": "2020-01-24T18:15:12.647", "references": [{"url": "https://www.us-cert.gov/ics/advisories/icsma-20-023-01", "tags": ["Third Party Advisory", "US Government Resource"], "source": "
[email protected]"}, {"url": "https://www3.gehealthcare.com/~/media/downloads/us/support/site-planning/site-readiness/gehc-gateway_project_implementation_guide_pdf.pdf", "tags": ["Product"], "source": "
[email protected]"}, {"url": "https://www.us-cert.gov/ics/advisories/icsma-20-023-01", "tags": ["Third Party Advisory", "US Government Resource"], "source": "af854a3a-2127-422b-91ae-364da2661108"}], "vulnStatus": "Modified", "weaknesses": [{"type": "Secondary", "source": "
[email protected]", "description": [{"lang": "en", "value": "CWE-434"}]}, {"type": "Primary", "source": "
[email protected]", "description": [{"lang": "en", "value": "CWE-20"}, {"lang": "en", "value": "CWE-434"}]}], "descriptions": [{"lang": "en", "value": "In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, B450 Version 2.X, B650 Version 1.X, B650 Version 2.X, B850 Version 1.X, B850 Version 2.X, a vulnerability in the software update mechanism allows an authenticated attacker to upload arbitrary files on the system through a crafted update package."}, {"lang": "es", "value": "En ApexPro Telemetry Server Versiones 4.2 y anteriores, CARESCAPE Telemetry Server Versiones v4.2 y anteriores, Clinical Information Center (CIC) Versiones 4.X y 5.X, CARESCAPE Central Station (CSCS) Versiones 1.X, B450 Versi\u00f3n 2.X, B650 Versi\u00f3n 1.X, B650 Versi\u00f3n 2.X, B850 Versi\u00f3n 1.X, B850 Versi\u00f3n 2.X, una vulnerabilidad en el mecanismo de actualizaci\u00f3n de software permite a un atacante autenticado cargar archivos arbitrarios en el sistema por medio de un paquete de actualizaci\u00f3n dise\u00f1ado."}], "lastModified": "2024-11-21T05:36:24.030", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:gehealthcare:apexpro_telemetry_server_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "4C5DD75E-7D4D-4B05-A84D-EDEAA2D23E59", "versionEndIncluding": "4.2"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:gehealthcare:apexpro_telemetry_server:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "A94476A1-B004-4561-918D-C41631F36D9F"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:gehealthcare:carescape_b450_monitor_firmware:2.0:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "C9607F33-BAC9-4F45-8685-9091CBBF4336"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:gehealthcare:carescape_b450_monitor:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "FDF68D5F-E436-492A-965E-0E9E254ACBFF"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:gehealthcare:carescape_b650_monitor_firmware:1.0:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "CF1DCCAF-A4E6-484B-953D-9352C85DE894"}, {"criteria": "cpe:2.3:o:gehealthcare:carescape_b650_monitor_firmware:2.0:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "D9A5B8CF-5214-4056-87CD-CD1F98142BD6"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:gehealthcare:carescape_b650_monitor:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "3B149BFB-BB31-4FFC-BC4D-299AB326136D"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:gehealthcare:carescape_b850_monitor_firmware:1.0:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "BDE014C2-9814-4137-9270-9B2AB55D3ABF"}, {"criteria": "cpe:2.3:o:gehealthcare:carescape_b850_monitor_firmware:2.0:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "AD10A852-3E11-4436-B771-53A9947A355E"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:gehealthcare:carescape_b850_monitor:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "7B8CA355-421A-44DE-A7EA-0BC0ACFDD697"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:gehealthcare:carescape_central_station_mai700_firmware:1.0:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "28F6C17B-2288-4EA1-B89F-6E1FED96ADD1"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:gehealthcare:carescape_central_station_mai700:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "4C2C8D13-A1C6-4DD1-9886-F925E2158C3A"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:gehealthcare:carescape_central_station_mas700_firmware:1.0:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "85D5EF4C-F118-4CA9-93C1-6366303F8893"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:gehealthcare:carescape_central_station_mas700:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "42991B9E-1D70-4A40-A283-162F2A73669B"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:gehealthcare:clinical_information_center_mp100d_firmware:4.0:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "2FE710E0-76E4-4F7E-890C-9AEB00F5DB13"}, {"criteria": "cpe:2.3:o:gehealthcare:clinical_information_center_mp100d_firmware:5.0:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "68B32A68-64CF-4579-B465-F1B8F4997C48"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:gehealthcare:clinical_information_center_mp100d:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "D0E93396-C7BB-4E53-8921-8251DC6A0F75"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:gehealthcare:clinical_information_center_mp100r_firmware:4.0:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "57D4B8E4-C481-446C-BF46-6FB6253344A1"}, {"criteria": "cpe:2.3:o:gehealthcare:clinical_information_center_mp100r_firmware:5.0:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "71F1DE32-2C25-4C0C-A4BF-30F5F3F19C70"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:gehealthcare:clinical_information_center_mp100r:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "057C6A3F-BD7E-4655-B9D9-1402C5259D59"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:gehealthcare:carescape_telemetry_server_mp100r_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "E7A592B9-9BE4-4096-B733-EE9A03D7A610", "versionEndIncluding": "4.2"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:gehealthcare:carescape_telemetry_server_mp100r:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "636B9839-E067-4BB0-A5FF-F3B4BE12AB50"}], "operator": "OR"}], "operator": "AND"}], "sourceIdentifier": "
[email protected]"}