CVE-2014-0751

The CIMPLICITY Web-based access component, CimWebServer, does not check the location of shell files being loaded into the system. By modifying the source location, an attacker could send shell code to the CimWebServer which would deploy the nefarious files as part of any SCADA project. This could allow the attacker to execute arbitrary code.
Configurations

Configuration 1 (hide)

OR cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\%2fscada_cimplicity:*:sim24:*:*:*:*:*:*
cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\/scada_cimplicity:4.01:*:*:*:*:*:*:*
cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\/scada_cimplicity:7.5:*:*:*:*:*:*:*
cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\/scada_cimplicity:8.0:*:*:*:*:*:*:*
cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\/scada_cimplicity:8.1:*:*:*:*:*:*:*
cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\/scada_cimplicity:8.2:*:*:*:*:*:*:*
cpe:2.3:a:ge:intelligent_platforms_proficy_process_systems_with_cimplicity:-:*:*:*:*:*:*:*

History

No history.

Information

Published : 2014-01-25 22:55

Updated : 2025-08-22 23:15


NVD link : CVE-2014-0751

Mitre link : CVE-2014-0751

CVE.ORG link : CVE-2014-0751


JSON object : View

Products Affected

ge

  • intelligent_platforms_proficy_hmi\%2fscada_cimplicity
  • intelligent_platforms_proficy_hmi\/scada_cimplicity
  • intelligent_platforms_proficy_process_systems_with_cimplicity
CWE
CWE-22

Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')